Guidance 4D probe; recognize the probe by way of the ID code; change the 4D push signal through the electrical relay for making the 4D probe operate Generally. 4.two.2 Most important board The main board may very well be divided into two areas: front-conclusion of the leading board and again-end of the most crucial board.
Dengan obshape baru yang cerdas dan desain layar penuh, mobilitas yang ditingkatkan, dan pengoperasian yang lebih nyaman, sistem yang andal dan terjangkau ini akan meningkatkan praktik umum dan sangat cocok untuk berbagai kebutuhan klinis.
Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat element login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.
The person is just not permitted to open the addresses and panel in the method, neither Take note: device disassemble is permitted. To ensure the procedure functionality and safety, only Mindray engineers or engineers approved by Mindray can execute routine maintenance.
Permits use of a number of scanned angles to kind an individual picture, causing Increased distinction resolution and enhanced visualization
Slash off cable ties connecting the leading unit to the Screen by diagonal reducing pliers, after which pull out the corresponding cable plugs.
Learn better diagnostic data by prolonged perspective of the anatomical structure on all linear probes
The DP-50 Qualified can be an impressive, substantial-efficiency Ultrasound Method engineered that will help you have the insights you may need. The Procedure’s strong engine and significant-speed processing supply excellent impression quality and a whole facts management Alternative.
Take note: Ahead of uploading the log, ensure the ultrasound system has long been connected to community, or else, the program may well alert “could not hook up with server” The server (smtp.
iZoom™ enables exact viewing of image from distance iWorks™ Protocol helps standardize workflow and lessen exam moments
Observe: On the keep track of, the brightness adjustment comes in advance of distinction. After readjusting the watch’s contrast and brightness, alter all preset and peripheral settings.
Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.
Right after changing the CPU module, vital file needs to be generated Yet again in accordance with the new MAC address and composed into HDD in the device. Or else, the configuration functionality of the solution might be shed. After getting rid of the CPU module, Get rid of panhead screws with washers (12 M3X6) set on the principle unit box, you might take from the board. Web site 118 Determine 8-29 Disassemble the User interface Assembly (1) Keep the upper fringe of control panel assembly, and open up up the control panel. Determine 8-thirty Disassemble the Control Panel Assembly (two) Just after taking away just one countersunk head self-tapping screw PT3X10 mounted about the user interface and acquire out the plug on the keyboard and the principle device connecting cables, you could possibly take away the control panel assembly.
Performance Check 5.five.one Take a look at Course of action Resolution Detection depth Geometric Posture Precision Blackout place take a look at Report the Examination photographs 5.5.two Test Content material The image used Here's only for reference, follow the image effect in the actual Notice: circumstance. Needs: Display: established the contrast and brightness in the scientific application value (or perhaps the default status) Procedure surroundings: dark place, simulating the medical software surroundings. Web page seventy six In problem which the transverse resolution testing targets are horizontally exhibited, document the negligible distance of two targets which might be Plainly acknowledged. Repeat the Procedure over for that transverse resolution testing targets at other depths. As demonstrated in determine beneath. Axial resolution ... Site seventy seven When using the convex probe, retain the transverse resolution tests targets to NOTE: be shown close to the midline. When employing a linear probe with steer perform, will not activate the steer perform when conduct the transverse resolution Dp50rb login test. Zoom inside the area where by the targets located if required. The diameter with the concentrate on stage at a certain depth is equal on the transverse resolution within the depth. Page 78 five.
Click on Agree and Continue to accept cookies and go straight to the internet site or click More details to determine comprehensive descriptions of the kinds of cookies and pick out whether to simply accept specified cookies although on the website.
Be aware: Guantee that you could possibly pull out and drive into the IO board sockets vertically when pulling out and assembling the IO board assembly about the place of your manage. Remove panhead screws with washers M3X6 (4) accustomed to protected the IO board, and then you might get out the IO board. Web site 116 Get rid of panhead screws with washers (2 M3X6) that happen to be preset on the most crucial unit, just take out the upper baffle then pull out two cables connecting the leading board to the facility module assembly.